On the basis of absorbing essence of similar products at
home and abroad, the company has researched and devel
oped this BC series DC brushless barrier gate. This product
adopts international advanced technology, with mechanical
and electrical integrated design, which fully realizes automa
tion and intelligence of operating, brings convenience,
safety and speed for using
Functions and Features
·Efficient DC brushless motor and precise gear reducer drive with mechanical and electrical control integrated.More flexible and convenient operation, safe and reliable for using, completely maintenance free during its service time.
·Adopts precise four-bar linkage mechanism and spring balance device which enable the barrier boom work with soft start-slow stop function in fast and stable without any impact. Reduces the driving power in maximum, extends its service life.
·Integrated machine core, small size with large power, wall-mounted installation, easy for assembling and disassembling.
·DC 24V low voltage brushless motor, adapts to global voltage (110~220±15%). It highlights for safer use, less noise, low heat output, frequently use, energy conservation and environmental protection.
·The combination of motor hall encoder and control unit ensures the control to mechanism moving position at the utmost.
·The dedicated controller system has high integration and strong logic performance. It can be connected with any toll system of roads and bridges,parking lots and so on.
·Intelligent speed adjustment efficiently reduces the trembling of the barrier boom, suitable for different
·High-sensitivity Auto-reverse function will prevent incorrect operation and other crash or hitting accidents.
·Open first anti-smash function: barrier boom will perform opening action once received an opening signal during the closing process.
·Humanized anti-collision boom dropping-out mechanism, when the vehicle accidently hits the barrier boom,the anti-collision mechanism will rotate the boom to avoid damage to the vehicle and the barrier gate.
·High-strength precision cast steel machine case, with outdoor metal powder electrostatic spraying surface treatment, waterproof and dustproof, protection class up to IP54
Technical Parameter List
Barrier Gate
|
BC3015
|
BC4020
|
BC5035
|
BC6050
|
Boom Length
|
Round boom
φ75, ≤3m;
Octagonal boom
80×46, ≤3m
|
Round boom
φ75, ≤4m;
Octagonal boom
80×46, ≤4m
|
Octagonal
boom
100×45, ≤5m
|
Octagonal
boom
100×45, ≤5m
|
Open/Close Time
|
1.5 sec
|
2.0 sec
|
3.5 sec
|
5.0 sec
|
Transmission Ratio
|
1:60
|
1:120
|
Max. Power
|
140w
|
Power Supply
|
AC110-240V±15%
|
Machine Case
|
1.5mm Steel Plate
|
Machine Case Size
(W×D×H)
|
325 × 240 × 962mm
|
Net Weight
|
38kg
|
Operating Temperature
Range
|
-40~+60 ºC (temperature under -20ºC should be equipped with electric
heating plate)
|
Driving Method
|
Brushless DC motor + Helical gear reducer
|
Protection System(IP)
|
54
|
Insulation Class
|
F
|
Relative Humidity
|
≤85%
|
Motor Unload Speed
|
2400r/min
|
Service Life
|
5 million times
|
Remote Control Distance
|
≤30m (empty environment, sunny weather)
|
Running Noise
|
<50dB
|
Surface Treatment
|
Outdoor metal powder electrostatic spraying
|
Machine Core Components
Assembly and Installation
1.Pre-Installation Check
Note:
*Barrier gate installation must be carried out by qualified technician; Installation must comply with relevant regulations. Before installation, please read this instruction manual carefully.
*Please definite the installation direction of the barrier gate to be leftward or rightward fixed.
*Please make sure that the boom will operate freely without any impediment.
*Please make sure the mounting base is strong enough and the size is suitable.
*Please make sure the installation spots for all the relative equipment are suitable to avoid any collision.
*Please check the accessories according to the packing list (Refer to column 9)
2.Basic Structure Installation
*Coil Installation Instruction:
Position of the induction coil: Generally, the induction coil size would be 2m(L) x 1m(W), its central axis should be right under the barrier boom, please refer to the figure 3.
*Fastening Screws Installation Instruction:
If the installation site didn't set with a foundation, then please make sure that the installation ground is strong enough to be fix with the barrier gate. Drill holes for fastening screws with diameter of 16mm, depth of 80mm, drive the M12 x 150mm fastening screw into the hole, then tighten the nut before withdrawing it.
If the installation site is concreted with foundation, please make sure the foundation depth is over 500mm, and the foundation area is over 450 x 450mm. Please pre-bury 3pcs PVC wiring tubes with
diameter of 25mm: 1 for induction coil wiring, which should be led towards roadside and should be 50mm underneath the ground. The other 2 tubes are for power supply and control unit wiring.Meanwhile, users can embed 4pcs M12 foundation screws and leave 70mm of the screw thread over the ground, keep a distance of 170 x 170mm; Or users can drill the hole after the foundation hardening, and use the equipped expansion bolts to finalize the installation, please refer to Figure 4.
*Barrier Gate Installation Instruction:
Put the barrier gate in the right place (Keep the boom dropping-out and vehicle passing on the same direction), make sure the barrier gate is vertical to the ground, align the press board to the anchor bolts, lock and fasten them.
*Barrier Boom Installation Instruction:
Place the barrier boom into boom tray, add plastic gasket on both sides, use the spanner to clamp
the boom by screws nuts. Please refer to Figure 5.
3.Boom Balance Adjustment
The tension of the spring is relative to the boom length, the spring has been assembled in the factory according to the different boom length, also the relative adjustments on boom operating speed
operating balance during opening/closing process has been set up before delivery. Spring tense
must be re-adjusted by professionals if there were any changes on the boom length or weight.
Please check and adjust according to the following steps.
1. Open the barrier gate side door and remove the upper cover.
2. Unplug the power cord.
3. Toggle the crank from the side door to unlock it(refer to column 6.7), manually adjust the boom to the place of 45 degrees then release the hand.
If the boom keeps stable on the place of 45 degrees' angle, indicating that it is with the best spring force.
4. If the spring force is too large or too small, then should be adjusted. First, loosen the nut on the top of the spring, clockwise rotating the screw to increase the tension of the spring, counter-clock-wise to decrease, then adjust the barrier boom again to its 45 degrees' angle position to check the spring tension.
5. Through repeating the above forth step to adjust the boom to its best balance,
then fasten the double nuts, adjustment is complete.
4.Power Wiring
The power module of the barrier gate has been connected to the control board before delivery. To ensure operational safety and avoid damage to the components, please disconnect the circuit breaker first, and then connect the L and N of AC power into the input port of circuit breaker.
5.Electrify Check
Please close the circuit breaker to connect the power after correctly wired. The indicator light on the control board will be on once the power is connected; After powering on, please press the open/-close button on the remote control, barrier gate will automatically detect the opening/closing limit switch (both limit switches are required to be detected). After detecting the opening/closing limit switch, the auto-detecting data will be saved automatically with a long sound of the buzzer, after which, the barrier gate will work normally.
6.Vertical Adjustment of Barrier Boom
If the barrier gate boom cannot open to its vertical position or close to its horizontal position. Please take the following steps to adjust it:
1. Open the barrier gate door, unplug the power cord.
2. Open and remove the upper cover.
3. Loosen the two fasten screws on rocker spring arm when the barrier boom is in erect. Adjust the boom to its horizontal position manually. Use the torque wrench to tighten the two fastening screws (locking force is 72 N·m)
4. Connect the power to work, check whether the boom opens/closes in place. If not, please re-adjust it after power off until the performance achieving the ideal state.
7.Manually Open/Closebarrier gate mechanism is on its self-locking position. If to manually open/close the boom at this time, please follow the steps as below:
1. Open the barrier gate door.
2. Unplug the power cord.
3. For leftward fixed type:
To close when boom in opened position, please counter-clockwise rotate the motor shaft with a specific tool to enable the barrier boom to move, after which barrier boom can be manually pressed down for closing.
To open when boom in closed position, please clockwise rotate the motor shaft with a specific tool to enable the barrier boom to move, after which barrier boom can be manually lifted up for opening. Please refer to Figure 9.
4. For rightward fixed type:
To close when boom in opened position, please counter-clockwise rotate the motor shaft with a specific tool to enable the barrier boom to move, after which barrier boom can be manually pressed down for closing.
To open when boom in closed position, please clockwise rotate the motor shaft with a specific tool to enable the barrier boom to move, after which barrier boom can be manually lifted up for opening.
Please refer to Figure 10
Note: Please stabilize the boom when manually open it, in order to avoid any unnecessary damage
caused by the spring tension.
8.Spring Configuration
Boom Length
|
Spring
|
3M Octagonal Boom 80x46 mm
|
Φ4.5x1pc
|
4M Octagonal Boom 80x46 mm
|
Φ5.5x1pc
|
5M Octagonal Boom 100x45 mm
|
Φ4.5 x1pc; Φ5.5 x1pc
|
6M Octagonal Boom 100x45 mm
|
Φ5.5x2pcs
|
Note: If the boom length is shorter than 4m, it's recommended to use 80x46mm octagonal boom,if longer than 4m, to use 100x45mm octagonal boom.
9.Control Board &Wiring Instruction
Technical Support
If there is any operation failure that can't be handled by your technical staff, please contact our authorized service representative or professional assistance.
Please provide the barrier gate model, product serial number, controller version and other information when contact us for technical support services, which you can find in the barrier gate machine case model plate.
Company Profile
EBO-TECH's service network covers more than 300 cities across China, with its business expanding to Southeast Asia, including Malaysia, and countries along the Belt and Road Initiative. Its projects span commercial sectors, office buildings, transportation hubs, charging stations, and residential communities. Notable locations include the Wangfujing business district, SKP shopping mall, Hong Kong West Kowloon Plaza, Tianfu International Airport, Huaxi Hospital, Hongya Cave Scenic Area, Longmen Grottoes, Wanda Plaza, Rainbow Group, Suzhou Jiaotou, Changsha City Investment, JLL, Shanghai Gubei Property, Hong Kong Wharf Group, and many more. Over a thousand key clients and tens of thousands of parking lots across the country have chosen EBO-TECH's products and services.
EBO-TECH's team upholds the values of "Integrity, Responsibility, Progress, and Cooperation" and adheres to the mission of becoming the "most trusted partner for customers. " EBO-TECH is dedicated to improving the management of every parking lot, making car owners' travel experiences more enjoyable, and ensuring that every car owner, and every parking space, feels secure and satisfied thanks to EBO-TECH's services.
Our Advantages
Self-owned factory
All products are self-developed
Directly to the cloud
Easier installation
Higher operational efficiency
Lower maintenance costs